Buffering Operation㻌
This function accumulates data while the system is in buffering operation.
Set necessary parameters in advance and start buffering.
㻌
㻌
㻌
All settings related to buffering cannot be changed during buffering.
㻌
㻌
Non-buffering status cannot be set by only stopping buffering.
㻌
㻌
Status Readout
This fuQFWLRQFKHFNVWKHVWDWXVRIPHDVXUHPHQWGDWDDFFXPXODWLRQ
Use this function for checking the accumulation status before reading out the
accumulated data. When the status is checked, the sensor head responds one of the
following conditions.
㻌
㻌
Status Details
Non-buffering
Buffering is not executed at all after turning on the power supply or
after initialization or buffering is stopped while waiting for the
trigger after buffering has started.
㻌
Wait for Tri
er
Waiting for the trigger after buffering has started.
㻌
Accumulating
Buffering has started and measurement data is being accumulated or
trigger has been generated and measurement data is being
accumulated.
㻌
Accumulation
Completed
The accumulation amount has reached the setting value or buffering
has stopped.
㻌
㻌
㻌
Last Data Point
The accumulation status can be read out from the data amount.
The "Final Data Point" will be set to "0" when the "Status Readout" is set to
Non-buffering or Wait for Trigger.
㻌
㻌
Ramco Innovations