Displacement Judgment
This function is used to set an upper limit (threshold a), lower limit (threshold
b), and hysteresis for the judgment of measurement values.
Item Panel display Setting range Function
Threshold a
㻌
-95000 to +95000
Sets threshold a,
threshold b and
hysteresis.
㻌
Threshold b 㻌 -95000 to +95000
Hysteresis 㻌
0 to +95000
㻌
㻌
The following default values apply.
㻌
Type
Diffuse reflection Specular reflection
Threshold
a
Threshold
b
Hystere
sis
Threshold
a
Threshold
b
Hystere
sis
30 mm +4mm -4mm 8ȝP +2mm -2mm ȝP
50 mm +10mm -10mm ȝP +5mm -5mm ȝP
85 mm +20mm -20mm ȝP +10mm -10mm ȝP
120 mm +60mm -60mm ȝP ---
250 mm +150mm -150mm 300ȝP ---
㻌
㻌
Set the value so that |Threshold a - Threshold b| is larger than the hysteresis × 2.
㻌
The decimal point position varies with each model.
㻌
㻌
3UHVVLQJ>Ÿ@IRUDWOHDVWVHFRQGVZLOOVHW7KUHVKROG D$OVRSUHVVLQJ>ź@
for at least 2 seconds will set Threshold b.
㻌
Ɣ6HWWLQJ3URFHGXUH
ί
Setting Threshold a
ὸ
1
Display the "Output Setting" screen
while the system is in setting mode.
㻌
2
3UHVVWKH>(17(5@NH\7KH-XGgment
Output Selection" screen will be displayed.
㻌
3
3UHVVWKH>'2:1@NH\RQFH7KH
"Threshold a" screen will be displayed.
㻌
4
3UHVVWKH>(17(5@NH\7KHSUHVHQW
threshold will be displayed. The leftmost
digit will be selected.