3-3-8㻌 COM Settings
Make COM settings through the control panel. No COM settings are possible with
serial communications commands.
㻌
Terminating Resistor Selection㻌
This function selects the terminating resistor for the sensor head connecting
to the host device over RS-422/485.
Be sure to select R3 if the system is connected to RS-422 equipment.
If a number of sensor heads are connected to RS-485 equipment, set R3 for the
terminating sensor and the rest of the sensors to OFF.
* The communication of the system, if unstable, may be improved by selecting R1
or R2.
㻌
Setting Function Panel display
OFF
Turn OFF terminating resistors
㻌
㻌
R1
Terminating resistor R1
㻌
㻌
R2
Terminating resistor R2
㻌
㻌
R3
Terminating resistor R3
㻌
㻌
* indicates the default value.
㻌
Ɣ6HWWLQJ3URFHGXUH
㻌
1
Display the "COM Setting" screen while
the system is in setting mode.
㻌
2
3UHVVWKH>(17(5@NH\7KH
"Terminating Resistor Selection" screen
will be displayed.
㻌
3
3UHVVWKH>(17(5@NH\7KHSUHVHQW
terminating resistor will be displayed.
㻌
4
3UHVVWKH>83@>'2:1@NH\WRFKDQJH
the terminating resistor. (Example:
Changing the resistor to OFF.)
㻌
5
3UHVVWKH>(17(5@NH\WRGHWHUPLQHWKH
terminating resistor.