Read Commands
Item Command Data Description Format
Read Command
Measurement
Va lu e Re a d
RMD -
-9500000 to
+9500000
-950.0000 to
+950.0000[mm]
FORMAT
ᵐᴾ
Read Received
Light Intensity
RID -
+00000 to
+04095
+00000 to +04095
FORMAT
ᵏᴾ
Alarm status
ROA -
+00000
Alarm OFF
+00001
Measurement Alarm ON
OUT1 Terminal
Read
RZA -
+00000
OUT1 OFF
+00001
OUT1 ON
OUT2 Terminal
Read
RZB -
+00000
OUT2 OFF
+00001
OUT2 ON
OUT3 Terminal
Read
RZC -
+00000
OUT3 OFF
+00001
OUT3 ON
All Outputs
Read
RMB -
-
Mesured value/Received
light intensity
/OUT1/OUT2/OUT3/AL
FORMAT
ᵑᴾ
*1. The data section consists of 5 digits (zero suppress is omitted) indicated in
decimal.
Buffering Commands
Item Command Data Description Format
Buffering Command
Buffering Mode
RBD WBD
+00000
Continuous
FORMAT
ᵏᴾ
+00001
Trigger
Buffering Rate
RBR WBR
+00001 to
+65535
+00001 to +65535
Accumulated Amount
RBC WBC
+00001 to
+03000
+00001 to +03000
Trigger Point
RTP WTP
+00001 to
+03000
+00001 to +
accumulated amount
Trigger Delay
RTL
WTL
+00001 to
+65536
+00000 to +65535
Trigger
Conditions
RTR WTR
+00000
At timing input ON
+00001
At or higher than
threshold
+00002
Lower than threshold
+00003
At an alarm occurred
+00004
At an alarm released
Threshold
RBL WBL
-9500000 to
+9500000
-950.0000 to
+950.0000[mm]
FORMAT
ᵐᴾ