Reset
The function resets the measurement value.
At the time of making a peak measurement, valley measurement, or peak-to-peak
measurement with external multi input (MI), the measurement value kept on hold
at the desired timing can be reset.
Input a specified pulse width as multi input.
The pulse width can be input into the high-function type through a communications
command.
For details,
refer to "2-4 Timing Chart".
All judgment outputs will be turned OFF when
Reset
is executed. This
function can be applied to judge each measurement object for peak, valley, o
r
peak-to-peak measurements.
The data will be in an unfixed status when "Reset" is executed, and the analog
output outputs the alarm set in the "Analog Output at Alarm" (initial value holds
the analog output immediately before the alarm), and the judgment output
becomes a HI judgment.
If Reset ON is executed by a communications command, the memory contents
will be cleared to zero after Reset is executed.
Ɣ6HWWLQJ3URFHGXUH
1
3UHVVWKH>83@>(17(5@NH\VWRJHWKHU
while in Run mode.
Reset will be executed.