CNG Signal Fixation Detection Counter
Specifies the number of times the CNG signal must be detected before the PBX proceeds the fax operation.
Value Range
1–3
Maintenance Console Location
3.4
[1-1] Slot—Card Property - IPCMPR (for KX-NCP500/KX-NCP1000/KX-TDE100/KX-TDE200)/IPCEMPR
(for KX-TDE600)
Programming Manual References
None
Feature Guide References
None
CED Signal Fixation Detection Time
Specifies the minimum length of time required for the CED (called station identification) signal to be detected
by the PBX.
Value Range
50 ´ n (n=1–100) ms
Maintenance Console Location
3.4
[1-1] Slot—Card Property - IPCMPR (for KX-NCP500/KX-NCP1000/KX-TDE100/KX-TDE200)/IPCEMPR
(for KX-TDE600)
Programming Manual References
None
Feature Guide References
None
T38 FAX Transmit Level (Network to PBX) A-Law
Specifies
the transmission level of G3 fax signals after being converted from T.38 protocol packets, when the
codec used is G.711A.
Value Range
-13–2 dB