3.23 [1-1] Slot—Card Property - Extension Type
The property for the extension cards can be specified.
KX-T7250 Transfer/Hold Key Mode
Selects whether the control signals sent by the Transfer and Hold buttons on
KX-T7250 PTs are reversed or
not.
Value Range
Mode 1: Does not switch the control signals
Mode 2: Switches the control signals
Maintenance Console Location
3.23 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None
Feature Guide References
None
SLT Pulse Dial Mode
Selects the type of pulse dial transmission appropriate to your area.
Value Range
Normal, Sweden
, New Zealand
Maintenance Console Location
3.23 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None
Feature Guide References
None
SLT Off Hook Time
Specifies the minimum length that a pulse dial sent from an SLT must be for the PBX to recognise it as an
off-hook signal.
Value Range
8 ´ n (n=3–255) ms
PC Programming Manual 229
3.23 [1-1] Slot—Card Property - Extension Type

Table of Contents

Other manuals for Panasonic KX-NCP500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic KX-NCP500 and is the answer not in the manual?

Panasonic KX-NCP500 Specifications

General IconGeneral
VoIP SupportYes
Operating SystemProprietary
TypeHybrid IP-PBX
VoIP CodecsG.711, G.729A
ProtocolsSIP, H.323
Operating Temperature0°C to 40°C
Analog ExtensionsYes
IP ExtensionsYes
Power SupplyAC 100-240 V, 50/60 Hz
SIP TrunksYes
Wireless (DECT) ExtensionsYes, with optional module
Weight4.0 kg
Humidity20% to 80% (non-condensing)

Related product manuals