Feature Guide References
None
Pulse Dial—Pulse % Break
Specifies
the % break for pulse digits. This is the ratio between the break (on-hook) signal and make (off-hook)
signal in a pulse dial.
Value Range
60 %, 67 %
Maintenance Console Location
3.46 [1-1] Slot—Card Property - EM type (KX-TDE series only)
Programming Manual References
None
Feature Guide References
None
Pulse Dial—Pulse Type
Selects the type of pulse dial transmission appropriate to your area.
Value Range
Normal, Sweden
, New Zealand
Maintenance Console Location
3.46 [1-1] Slot—Card Property - EM type (KX-TDE series only)
Programming Manual References
None
Feature Guide References
None
Pulse Dial—Pulse Inter-digit Pause
Specifies
the length of the pulse inter-digit pause. This allows the telephone company to have enough time to
accept the dialled digits correctly.
Value Range
630 ms, 830 ms, 1030 ms
398 PC Programming Manual