Alarm Setup ScreenAlarm Setup Screen
LASAIR II Operator’s ManualLASAIR II Operator’s Manual
PagePage
5-135-13
Printing on AlarmPrinting on Alarm
This feature automatically prints one of the following error reports when anThis feature automatically prints one of the following error reports when an
alarm occurs:alarm occurs:
Print-on-Alarm can be enabled or disabled on Print-on-Alarm can be enabled or disabled on the LASAIR II’s Alarm Setupthe LASAIR II’s Alarm Setup
Screen or on tScreen or on the HTML page. See he HTML page. See “Printout and Legend” on “Printout and Legend” on pagepage 8-21.8-21.
TTo enable o enable Print-on Alarm:Print-on Alarm:
11 From the Main Display Screen, open the Sampling Setup Screen byFrom the Main Display Screen, open the Sampling Setup Screen by
pressing the Main Setup icon softkeypressing the Main Setup icon softkey..
22 From the Main Setup Screen, open the Alarms Setup Screen by pressingFrom the Main Setup Screen, open the Alarms Setup Screen by pressing
the Alarms the Alarms softkeysoftkey..
33
Enable the edit mode by Enable the edit mode by pressing the Enter softkey.pressing the Enter softkey.
44 If necessaryIf necessary, press the Enter softkey to activate the a, press the Enter softkey to activate the alarm function.larm function.
55
Navigate to the “printer” icon Navigate to the “printer” icon and press the Enter softkeyand press the Enter softkey. The icon will. The icon will
appear to be depressed below the surface of the LCD display.appear to be depressed below the surface of the LCD display.
66 Press Press the the Return Return icon icon softkey softkey to to exit exit the the Alarm Alarm Setup Setup Screen.Screen.
To Edit the Alarm Setup:To Edit the Alarm Setup:
11 press the Enter button.press the Enter button.
22 Use the tab and back tab keys to move from the Particle Alarm Setup Screen andUse the tab and back tab keys to move from the Particle Alarm Setup Screen and
the Analog Alarm Setup Screen and to move to the major areas within eachthe Analog Alarm Setup Screen and to move to the major areas within each
setup screen.setup screen.
33 Use the Arrow keys to move within an Use the Arrow keys to move within an alarm matrix. Use the Enter key toalarm matrix. Use the Enter key to
initiate and to confirm changes.initiate and to confirm changes.
To move back and forth from Particle Alarms and Analog Alarms:To move back and forth from Particle Alarms and Analog Alarms:
press the “Tpress the “Tab softkey” when you are out of edit mode.ab softkey” when you are out of edit mode.
•• FFlloow w EErrrroorr •• PPaarrttiicclle e AAllaarrmm
•• LLaasseer r EErrrroorr •• AAnnaalloog g AAllaarrmm