Connecting two Cashless units MDB
Starting from firmware rev.2.00, EAGLE can control 2 cashless units MDB that are identified with the following
addresses:
MDB Cashless 1 Address 60H
MDB Cashless 2 Address 10H
The price list for Cashless MDB (in Fn37) is only connected to Cashless 2 (address 10H).
The presence of two Cashless Systems MDB makes it impossible to manage the Audit file of the local key reader,
which must not be connected.
When connecting an OPTO MDB reader, which is configured as a double Cashless MDB unit (Cashless PIT key
+ Cashless Smartphone), you CANNOT connect a local Paytec key reader, too.