49
Reset audit
password -----
Enable Service
reset key ?
Send extended
audit ?
Test Ext. audit
full ?
Ext. Audit elem.
---- of ----
No.
readouts:
1
Confirm
reset ?
Price list
EVA-DTS 6.0 ?
New Password
-----
NO RESET data LR
with DataKey
Fn12 – Audit parameters
You can reset here the whole Audit of a system or read information about Audit readouts (password required).
Password by default: 00000.
How to modify password : enter 00000 and press
then enter the new
password and press
again to confirm (the new password is now valid).
Adjust storage Identifiers Audit LA1_, as required by standard EVA-DTS.
N Standard Paytec: LA1_0 = Cash; LA1_1 = Card.
Y Standard EVA-DTS 6.0: LA1_0 = full price; LA1_1-LA1_4 = 5 lists with
reduced prices.
Warning: should you need to edit price list type, remember to reset Audit before.
In the AUDIT file, "MA5*0*AUDIT FILE REVISION 0102" identifies Audit lists LA1 in no/EVA-DTS mode, while
"MA5*0*AUDIT FILE REVISION 0002" identifies Audit lists LA1 in EVA-DTS 6.0 mode.
N The Audit file cannot be reset with a Service Key.
Y The Audit file can be reset with a Service Key (all data are reset both LR
and IN).
Service Key can be used when a Paytec PIT key reader is connected.
N When downloading Audit data with a DataKey, the partial data LR in the
Audit file are usually reset (STANDARD).
Y When downloading Audit data with a DataKey, the partial data LR in the
Audit file are NOT reset.
Other counters are not modified:
- the counter no. Audit readouts is not incremented
- date/time of Audit readout is not updated
- data are not reset in extended Audit
- credit survey code is not incremented
N Standard Audit.
Y Extended Audit.
Data from extended Audit can be processed with "Audit View" (PC
application).
N When the memory is full, old data are overwritten.
Y When the memory is full, EAGLE is inhibited (LED flashing yellow).
No. operations that have been stored in extended Audit.
No. readouts completed.
N Audit reset aborted.
Y Audit reset confirmed: data are cancelled and counters are reset since
initialization.