Pentair FLECK 5800 SXT - Commands; Setting the Time of the Day (TD); Basic Programming; Day of Override (DO)

Pentair FLECK 5800 SXT
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Fleck 5800 - SXT - Programming
Ref. MKT-IM-004 / A - 18.04.2017 47 / 92
6.2. Commands
6.3. Setting the time of the day (TD)
Set the time in the system.
6.4. Basic programming
Note
Menus are displayed in a defined and incremental order.
6.4.1. Day of Override (DO)
Determine the maximum number of days of operation without regeneration.
2. Data display
3. PM indicator → Appears if controller set in US unit.
4. Flow indicator → Flashes when outlet flow is detected.
5. x1000 indicator → Appears when the displayed number is bigger than 9999.
6. Programming icon → Appears in programming modes.
7. Service icon → Appears in service mode;
→ Flashes if a regeneration cycle has been queued.
8. Error /
Information icon
→ Appears in case of error, see page 75, or in diagnostic mode, see
page 61.
A Press to pass to the next step.
B Use and to adjust the values.
A Press and hold or until the programming icon replaces the service
icon and the parameter display reads TD.
B Set the time with or .
C Press to validate the selection and return to the service mode, or wait
for 10 seconds.
A Press and simultaneously for 5 seconds to enter the menus
sequence.
B Select the number of days of Override with and .
C Press to validate the selection and advance to the next parameter.