6.5.10.2 Fixed reserve capacity (RC)
Set the reserve capacity.
Note
The fixed reserve capacity parameter is only available if this option has been set in reserve
selection.
Note
The fixed reserve capacity is a fixed volume and does not change if the unit capacity or
feedwater hardness are changed.
Note
The fixed reserve capacity can be set up to a volume equivalent to 50% of the initial
volumetric capacity.
6.5.11. Days override (DO)
Set the maximum number of days between regeneration cycles.
Note
This parameter allows to set the maximum amount of days that the system can stay in
service mode without a regeneration.
Mandatory
In time clock mode the setting of this parameter is mandatory and the electronic will need
at least one regeneration day activated.
Note
Setting the parameter to "OFF" disables this function.
Note
The number of days can be set from OFF, or 1 to 99 days.
U Press or to set the safety factor.
V Press to validate the selection and move to the next parameter.
W Press or to set the reserve capacity.
X Press to validate the selection and move to the next parameter.
Y Press or to set the days override.
Z Press to validate the selection and move to the next parameter.