EasyManua.ls Logo

Pentair FLECK 5800 SXT - Error Detection; Error Types and Causes; Motor Stall; Cam Sense Error; Motor Run-ON Error; Cycle Sense Error

Pentair FLECK 5800 SXT
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Fleck 5800 - SXT - Troubleshooting
Ref. MKT-IM-004 / A - 18.04.2017 79 / 92
10.1. Error detection
Errors codes appear on the service display.
Note
It can take up to 1 minute before an error can be detected and displayed.
10.2. Error types and causes
10.2.1. Motor stall / cam sense error
Note
No states changes in the optical sensor detected for six seconds.
10.2.2. Motor run-ON error / cycle sense error
Note
An undesired optical sensor state change occurred.
A Unplug the unit and plug back in. Allow the controller to attempt to find
position again.
B If the unit doesn’t find position, unplug, open the cover (see “Replacing the
controller”, page 70) and verify the optical sensor is in place with the wires
connected to the circuit.
C Verify the motor and gearing components are in good condition and
assembled properly.
D Check the valve and verify that the piston travels freely.
E Replace / reassemble the various components as necessary.
F Plug the unit back in and observe its behaviour.
G If the error reoccurs, unplug the unit.
H Put it into bypass.
I Contact dealer.
A Non critical error, extra optical sensor pulse detected.
B Press any button to clear the error.
C Press to advance motor to clear error.

Table of Contents

Other manuals for Pentair FLECK 5800 SXT

Related product manuals