82
PEP Ergo D-150
L = 0.98 – 1.50 m
PEP Ergo D-250
L = 1.47 – 2.50 m
PEP Ergo D-350
L = 2.26 – 3.50 m
PEP Ergo D-400
L = 2.51 – 4.00 m
PEP Ergo D-500
L = 3.26 – 5.00 m
1.00 30.0 30.0
1.10 30.0 30.0
1.20 30.0 30.0
1.30 30.0 30.0
1.40 28.4 30.0
1.50 26.4 30.0 35.0 35.0
1.60 35.0 35.0
1.70 32.8 35.0
1.80 30.7 35.0
1.90 29.1 35.0
2.00 28.1 35.0
2.10 27.2 35.0
2.20 26.4 34.0
2.30 25.7 32.3 40.0 40.0
2.40 24.2 29.4 40.0 40.0
2.50 22.4 26.2 40.0 40.0
2.60 37.8 40.0 40.0 40.0
2.70 35.1 40.0 40.0 40.0
2.80 33.0 40.0 40.0 40.0
2.90 31.1 40.0 40.0 40.0
3.00 29.6 40.0 40.0 40.0
3.10 28.1 38.6 37.7 40.0
3.20 26.9 34.7 35.6 40.0
3.30 25.0 31.5 33.7 40.0 40.0 40.0
3.40 23.1 28.6 32.3 40.0 40.0 40.0
3.50 21.2 25.8 30.7 39.3 40.0 40.0
3.60 28.6 35.9 40.0 40.0
3.70 26.7 32.9 40.0 40.0
3.80 24.9 30.2 40.0 40.0
3.90 23.1 27.8 40.0 40.0
4.00 21.4 25.3 40.0 40.0
4.10 39.0 40.0
4.20 36.3 40.0
4.30 33.8 39.0
4.40 31.6 36.7
4.50 29.6 34.3
4.60 27.8 32.1
4.70 26.1 30.1
4.80 24.5 28.2
4.90 23.0 26.4
5.00 21.4 24.7
A18 Slab props
PEP 30 with Base MP 50
Permissible prop load [kN] according to type test
Extension
length [m]
Outer tube
bottom
Inner tube
bottom
Outer tube
bottom
Inner tube
bottom
Outer tube
bottom
Outer tube
bottom
Inner tube
bottom
Inner tube
bottom
Note:
■
PERI PEP Ergo D-150, PEP Ergo D-250, PEP Ergo D-350, PEP Ergo D-400 and
PEP Ergo D-500 Props fulfil Prop Class D load-bearing capacity requirements of
DIN EN 1065.
■
In addition, the PEP Ergo D-250 Prop fulfils Prop Class B requirements as stipulated
in DIN EN 1065.
■
General Building Inspectorate Approval Z-8.311-934 for PERI PEP Ergo D-150 and
PEP Ergo D-250.
■
General Building Inspectorate Approval Z-8.311-941 for PERI PEP Ergo D-350,
PEP Ergo D-400 and PEP Ergo D-500.
SKYDECK Panel Slab Formwork
Instructions for Assembly and Use – Standard Configuration
SKYDEKC AuV_ex_791458.indb 82 13.12.16 16:58