Input
69
Group
Parameter
Description
Setting range
Set value
5
503 End backtack speed 100 - 1500 700
504 Soft start speed 100 - 3500 1500
505 Soft starting stitches 0 - 15 0
6
601
Move roller presser and feed wheel stepping motor
602
Inputs: 0123456789ABCDEF
0= needle mid-point (E16)
1= needle end position (E15)
2= intermittent coding (E14)
3= free (E13)
4= free (E12)
5= free (E11)
6= free (E10)
7= free (E9)
8= emergency key (E8)
9= free (E7)
A= knee switch (E6)
B= photo cell (E5)
C= start inhibitor (E4)
D= single stitch key on the machine head (E3)
E= half stitch key on the machine head (E2)
E= reversing key on the machine head (E1)
603 Machine drive home position
1591
8 ± 2
1593
11 ± 2
604 Run cold start
605
Stitch formation with stepping motors by handwheel
(only with BDF S3)
606 Display nominal value transmitter values
7
701 P-section speed regulator 1 - 50 30
702 I-section speed regulator 0 - 100 50
703 P-section position controller 1 - 50 20
704 D-section position controller 1 - 100 30
705 Time for position controller 0 - 100 25