EasyManua.ls Logo

Pfaff 3511-2/01 - Parameter List (Groups 6-10)

Pfaff 3511-2/01
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adjustment
90
Group
Parameter
Description
User level
Setting range
Set value
6
668 Thread wiper / thread blower
1 = on; 0 = off
B,C 0 - 1 1
7 700 Needle position "0"
(needle reference position)
B,C 0 - 255 0
702 Needle position "1" (needle lowered) B,C 0 - 255 80
703 Needle position "2" (take-up lever raised) B,C 0 - 255 226
705 Needle position "5"
(magnetic thread trimming / end of cutting si-
gnal "1", start of tacting of cutting signal "1")
B,C 0 - 255 200
706 Needle position "6"
(pneumatic thread cutting / start of cutting
signal "2")
B,C 0 - 255 80
707 Needle position "9"
(start thread tension release / start thread
catcher)
B,C 0 -255 164
715 Switch on time for thread wiper [ms] B,C 0 - 2000 90
718 Stop brake tacting
0 = brake off
B,C 0 - 100 0
719 Tacting adjustment A4 (presser foot)
0 = 100 % power up
B,C 10 - 60 40
722 Acceleration ramp
1 = fl at; 50 = steep
B,C 1 - 60 50
723 Brake ramp
1 = fl at; 50 = steep
B,C 1 - 60 40
729 Start delay after lowering presser foot [ms] B,C 10 - 2000 150
730 Delay for raising presser foot after seam
end [ms]
B,C 0 - 2000 50
734 Tacting output A2 (thread trimming) B,C 10 - 60 40
760 No. of stitches for remaining thread after
response of bobbin thread monitor with
direct bobbin thread monitoring (with sensor)
Multiplier for the fi xed value "200" for deter-
mining initial value for stitch counter with in-
direct bobbin thread monitoring (with stitch
counting)
A,B,C 0 - 250 5