Input P45 PD2
48
Group
Parameter
Description
User level
Setting range
Set value
6
668 Thread wiper
ON = yes,
OFF = no
B ON - OFF OFF
688 Thread tension release in conjunction with
presser foot lift during intermediate stop, if
parameter 636 is at ON
ON = on, OFF = off
B ON - OFF OFF
7
700* Needle position 0
Needle reference position
B 0 - 255 27
702* 1
st
needle position (lowered)
(no. of degrees on balance wheel - 220°)
B 0 - 255 79
703* Thread take-up lever position raised
(no. of degrees on balance wheel - 70°)
B 0 - 255 235
705* End of cutting signal
(no. of degrees on balance wheel - 0°)
B 0 - 255 185
706* Start of cutting signal
(no. of degrees on balance wheel - 173°)
B 0 - 255 85
707* Start thread tension release
(no. of degrees on balance wheel - 17°)
B 0 - 255
2231, 2235, 2545/46 195
2335 120
710* Needle position raised
(no. of degrees on balance wheel - 0°)
B 0 - 255 185
715 Switch-on time [ms] for thread wiper B 0 - 9000 60
718 Stop brake tacting
( 0 = brake off)
B 0 - 50
2231, 2235, 2545/46 15
2335 10
719 Tacting output (presser foot)
100 = 100 % starting
B 10 - 100 100
721 Tacting output (feed adjustment)
100 = 100 % starting
B 10 - 100 100
* = These parameters remain unchanged when the set parameter values are reset, see
Chapter 10.01.02 Resetting the set parameter values.