P45 PD2 Input
49
Group
Parameter
Description
User level
Setting range
Set value
7
722 Acceleration ramp for sewing motor
1 = fl at, 50 = steep
B 0 - 50 22
723 Brake ramp for sewing motor
1 = fl at, 50 = steep
B 1 - 50 22
727 Bobbin monitoring effective
ON = sewing motor stop and signal
lamp on
OFF = signal lamp on
B ON - OFF ON
729 Start delay after lowering presser foot [ms] B 10 - 9000 120
730 Lift delay for presser foot at end of seam B 0 - 9000 50
734 Tacting output
(cutting magnetic)
B 1 - 100
0
74 8
Function of "threading aid" key
1 = threading aid + needle raised without
trimming
2 = needle position change
3 = single stitch
4 = not allocated
5 = tack inversion
6 = tack suppression
B 1 - 6
1
761 Extension thread tension release / thread
pulling [ms]
B 0 - 80 0
770 Lifting delay for presser foot when pedal
position is "-1" [ms]
B 10 - 1000 150
775 Stop time for ornamental tack [ms] B 10 - 1000 150
789 Needle position 10 (bearing position) B 0 - 255 248
797 Hardware test
OFF = off, ON = on
C ON - OFF OFF
798 User level
0 = user level A
1 = mechanic level B
11 = service level C
A 0 - 20 0
* = These parameters remain unchanged when the set parameter values are reset, see
Chapter 10.01.02 Resetting the set parameter values.