8.2.2 PANEL FACTORY (+)
¶ Operation items
The factory menu section of the panel side is displayed.
Panel Factory Function
Displays the Factory menu, which enables adjustment of the panel via the screen display.
1. Character display area
• Mask indication during Panel Factory mode
If the Mask indication is set during Panel Factory mode, the GUI indication is displayed for 1 second at one layer
of the panel factory menu, followed by switching to the mask and drive sequence that have been set. For details
on the communication format with the main microcomputer.
No. Display Item Content
RS-232C
Command
1 PANEL INFORMATION The software version and backup status of the DIGITAL Assy are displayed. QST
2 PANEL WORKS The counts of the Pulse Meter and Hour Meter are indicated. QIP
3 POWER DOWN The power-down history is indicated. QPD
4 SHUT DOWN The shutdown history, as detected by the Module Microcomputer, is displayed. QSD
5 PANEL-1 ADJ (+) The SUS waveform and drive power can be adjusted. –
6 PANEL-2 ADJ (+) The panel white balance and ABL can be adjusted. –
7 PANEL REVISE (+) The panel degradation correction level can be set. –
8 ETC (+) Copying of backup data and clearance of various data can be done. –
9 RASTER MASK SETUP (+) The mask screen (PASTER) is displayed. MKS
10 PATTEN MASK SETUP (+) The mask screen (PATTERN) is displayed. MKS
11 COMBI MASK SETUP (+) The mask screen (COMBI) is displayed. MKC