Chapter 19-Collaboration Server Administration and Utilities
Polycom, Inc. 19-19
Traps
Three types of traps are sent as follows:
1 ColdStart trap. This is a standard trap which is sent when the MCU is reset.
Figure 1 An Example of a ColdStart Trap
2 Authentication failure trap. This is a standard trap which is sent when an unauthorized
community tries to enter.
Figure 2 An Example of an Authentication Failure Trap
coldStart notification received from: 172.22.189.154 at 5/20/
2007 7:03:12 PM
Time stamp: 0 days 00h:00m:00s.00th
Agent address: 172.22.189.154 Port: 32774 Transport: IP/UDP
Protocol: SNMPv2c Notification
Manager address: 172.22.172.34 Port: 162 Transport: IP/UDP
Community: public
Enterprise: enterprises.8072.3.2.10
Bindings (3)
Binding #1: sysUpTime.0 *** (timeticks) 0 days
00h:00m:00s.00th
Binding #2: snmpTrapOID.0 *** (oid) coldStart
authentication Failure notification received from:
172.22.189.154 at 5/20/2007 7:33:38 PM
Time stamp: 0 days 00h:30m:27s.64th
Agent address: 172.22.189.154 Port: 32777 Transport: IP/UDP
Protocol: SNMPv2c Notification
Manager address: 172.22.172.34 Port: 162 Transport: IP/UDP
Community: public
Enterprise: enterprises.8072.3.2.10
Bindings (3)
Binding #1: sysUpTime.0 *** (timeticks) 0 days
00h:30m:27s.64th
Binding #2: snmpTrapOID.0 *** (oid) authenticationFailure
Download from Www.Somanuals.com. All Manuals Search And Download.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom RMX 1800 and is the answer not in the manual?

Polycom RMX 1800 Specifications

General IconGeneral
BrandPolycom
ModelRMX 1800
CategoryServer
LanguageEnglish

Related product manuals