Section V Parameter Function Table
64
FWD torque up limit switch 2
Detail read C parameter system C15.
FWD torque up limit switch 3
REV torque up limit switch 1
Combine REV torque upper limit switch.
Detail read C parameter system C16.
REV torque up limit switch 2
REV torque up limit switch 3
Vector control mode, speed control mode
and torque control mode switching.
Disconnected status: Speed Control
Closed Status: torque control
Detail C parameter set C18
Edge-triggered, the fault occurred on the
current failure to confirm or not confirm
JOG forward running command
JOG reverse running command
JOG order (as F35 setting )
JOG running order,the direction as F35
setting direction
Acceleration and deceleration
forbid command
Keep current status , prohibit acceleration
and deceleration movement.
Motor 1、2 change
Invalid status : Motor 1
Valid status : Motor 2
Off-status :motor 1;
Close status :motor
2.
Free stop :
free stop ,No starting
command 1S later,allow running again.
Up command ,detail A38~A42.
Down command ,detail A38~A42.
Auto-run feature programs canceled
Cancel program running function.
Automatic procedures to suspend
operation
Program running start mode
Program running start mode
Program running stop mode
Program running stop mode
Edge trigger, frequency inverter pulse
counter O53 clearance
Edge-triggered, set the pulse counter input
terminal
Edge-triggered pulse counter counts o5
maximum load o53
Edge trigger,pluse counter O53 loading up
count value O55.