1 bit: Timing mode
0 Boot time , timing of runnig and breaking
1 Running timing,only timing of running
10 bit:Reserved
100 bit:Reserved
1000 bit:Reserved
Set timeing of limit time 1 , Time limit 2
Actual limit time on the basis of the set time multiplied by a run time multiple, such time
multiple set by the ten bit of F49, refer to F49 instructions.
1 bit: Program running functions intelligent
To use the program to run PLC functionality requires setting the bit to 1.
Multi-segment speed run only need to set the corresponding multi-stage o36 ~ o46-speed
switching can be used without the need to set this parameter.
0: Program running functions cancel
1: Program running function intelligent
10 bit: Define program runs or direction settings of multi-segment speed running
0: the direction decided by the H40 ~ H46
1: The directiondecided by the keyboard or terminal
100 bit:Define program runs or acceleration and deceleration time settings of multi-segment
speed running
0: deceleration time decided by the H26 ~ H39
1: The acceleration and deceleration time determined by terminal