5. Reinstall the Drive Roller, see "Drive Roller Replacement" on page168.
6. Reinstall the Take-up Roller, see "Take-up Roller Replacement" on page178.
7. Center and square the running belt onto the Take-up and Drive rollers, tension the
belt to specification and verify the belt tracking, see "Running Belt Tension and Track-
ing Adjustment" on page67.
8. Reinstall the hood cover, see "Covers and Panels Replacement" on page86, and
left/right Landing Trim covers, see "Covers and Panels Replacement" on page86.
9. Connect the power cord and switch the ON/OFF circuit breaker ON.
10. Reset the maintenance Belt Rating after a new deck/belt replacement. Open the
Maintenance Belt Rating screen and select Replacement (Access Hardware Val-
idation service menu (51765761) , select : Maintenance > Belt Rating > Replace-
ment).
11. Do the Operation Verification tests (see "Operation Verification" on page24) and
return to service.
Common Frame Belt and Deck Replacement
Review entire procedure before starting.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 194
6 Replacement Procedures
Running Belt and Deck Replacement Procedure