7. Connect the power cord and switch the power ON.
8. Verify the Drive Belt alignment and tension to specification. see "Drive Belt Tension
and Alignment Adjustment" on page58.
9. Reinstall the hood cover, see "Hood Cover Replacement" on page88.
10. Do the Operation Verification tests (see "Operation Verification" on page24) and
return to service.
Common Frame Drive Motor Replacement
Review entire procedure before starting.
Removal
1. Switch the power OFF and unplug the power cord.
2. Remove the hood cover, see "Hood Cover Replacement" on page88.
3. Disconnect the Motor Controller "MTH" and "MOTOR" electrical connections:
a. Remove the two left side MC fasteners and loosen the two right side fasteners.
Then slide the MC base to the left and remove the MC from the fasteners, see
"Motor Controller (MC) Replacement" on page123.
b. Lift the front of the MC just enough to access and disconnect the MC "MTH" I/O
connector. Then lift the rear of the MC just enough to access and disconnect
the MC "MOTOR" I/O connector.
c. Remove the MOTOR interface cable from the three frame routing cable
clamps.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 160
6 Replacement Procedures
Drive Motor Replacement

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor Experience 700 Series and is the answer not in the manual?

Precor Experience 700 Series Specifications

General IconGeneral
BrandPrecor
ModelExperience 700 Series
CategoryTreadmill
LanguageEnglish

Related product manuals