Configuration MP.11-R Installation and Management
Management Parameters
96
Serial Configuration Settings
The serial port interface on the unit is enabled at all times. See “Serial Port” in the Tsunami MP.11/QB.11 Reference
Manual for information about how to access the CLI interface through the serial port. You can configure and view
following parameters:
Serial Baud Rate: Select the serial port speed (bits per second). Choose between 2400, 4800, 9600, 19200, 38400,
or 57600; the default Baud Rate is 9600.
Serial Flow Control: Select either None (default) or Xon/Xoff (software controlled) data flow control. To avoid
potential problems when communicating with the unit through the serial port, Proxim recommends that you leave the
Flow Control setting at None (the default value).
Serial Data Bits: This is a read-only field and displays the number of data bits used in serial communication (8 data
bits by default).
Serial Parity: This is a read-only field and displays the number of parity bits used in serial communication (no parity
bits by default).
Serial Stop Bits: This is a read-only field that displays the number of stop bits used in serial communication (1 stop
bit by default).
The serial port bit configuration is commonly referred to as 8N1.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Proxim Tsunami MP.11-R and is the answer not in the manual?

Proxim Tsunami MP.11-R Specifications

General IconGeneral
BrandProxim
ModelTsunami MP.11-R
CategoryWireless Router
LanguageEnglish

Related product manuals