Q24/Q48 Tape Library Installation and Operations Manual
Error
Code
Description
User Action
Critical Component Status
99
Sled home sensor not
found
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Media changer controller defect.
Slider home sensor defect (mechanics,
electronics).
Cabling incorrect.
9A
Rotation home sensor
not found
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Media changer controller defect.
Rotation home sensor defect (mechanics,
electronics).
Cabling incorrect.
9B
Sled position sensor
(prism sensor) not
found,
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Media changer controller defect.
Sled home sensor defect (mechanics,
electronics).
Cabling incorrect.
9C
Gripper range out of
specification
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Gripper motor not connected or defect.
Media changer controller or distribution
boards defect.
Check gripper mechanism according
stiffness in movement
9D
Slider range out of
specification
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Slider motor not connected or defect.
Media changer controller or distribution
boards defect.
Check slider mechanism according
stiffness in movement.
9E
Elevator range out of
specification
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Elevator motor not connected or defect.
Media changer controller or distribution
boards defect.
Check elevator mechanism according
stiffness in movement.
9F
Rotation range out of
specification
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Rotation motor not connected or defect.
Media changer controller or distribution
boards defect.
Check rotation mechanism according
stiffness in movement.
© Copyright QUALSTAR 2015 77