Q24/Q48 Tape Library Installation and Operations Manual
Critical Component Status
specification
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Sled motor not connected or defect.
Media changer controller or distribution
boards defect.
Check s
led mechanism according stiffness
in movement.
(Import/Export
several occurrences
contact technical support
Mail Slot release mechanism defect
(Note: only relevant for
8U)
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Sled motor #2 not connected or defect.
Sled motor #2 voltage too low.
Sled home sensor #2 defect.
Sled sensor #2 connecting cable
damaged.
Media changer controller or distribution
boards defect.
Check top sled mechanism (gears, sheet
guide locking) according stiffness in
block within the
expected range
(Note: only relevant for
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Cabling incorrect.
Check top sled mechanism (gears, sheet
guide locking).
not found
(Note: only relevant for
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Media changer controller defect.
Sled home sensor #2 defect (mechanics,
electronics).
found
(Note: only relevant for
8U)
Run ‘Wellness Test’, after
several occurrences
contact technical support
Media changer probably defective.
Media changer controller or distribution
boards defect.
Elevator sensor defect (mechanics,
electronics).
Cabling incorrect.
Elevator motor not connected or defect.
Elevator motor voltage to low.
Check elevator mechanism according