Operation Quantron E 4
42
Recalculate flow factor
1. Weigh the spread fertiliser amount.
2. Input the weight of discharged fertiliser in the input field of the Input collected
weight menu.
See also 4.9.2:
Input of values using the cursor keys, page 76.
3. Confirm the input by pressing the Enter key.
The new value is saved in the operator panel.
The display shows the Flow Factor Calculation menu.
Figure 4.18:Flow factor calculation menu
[1] Display of previously saved flow factor
[2] Display of new calculated flow factor
4. Specify the flow factor.
To accept the newly calculated flow factor press the Enter key.
To confirm the previously saved flow factor press the ESC key.
The flow factor is saved.
The Fertiliser Settings menu is displayed.
5. Press the ESC key to return to the previous menu
or
Press the Menu key to return to the Operating Screen.
n CAUTION
Danger of injury caused by automatic adjustment of
the drop point
On the AXIS 50.1 W the alarm move to drop point intervenes.
After actuating the Start/Stop button, the drop point is automati-
cally approached using the electrical setting cylinder to the pre-set
value. This can cause injuries and material damage.
Before actuating the Start/Stop button, ensure that no one
is in the danger area of the machine.