Operation Quantron E
43
4
4.4.5 Drop point (L+R)
When the Quantron E is connected to an AXIS 50.1 W fertiliser spreader, the
drop point is actuated and adjusted electrically.
1. Switch from the Fertiliser settings menu to the drop point L menu.
2. Determine the position for the drop point from the fertiliser chart.
3. Input the determined value in the input field with the arrow keys:
Arrow up: Value increases.
Arrow down: Value decreases.
4. Press the Enter key.
A message appears in the display asking for the new setting to be confir-
med.
See 5.1:
Meaning of alarm messages, page 77
The fertiliser settings window appears in the display with the new drop point (L
and R).
If the drop point is blocked Alarm 17 appears; See 5.1:
Meaning of alarm mes-
sages, page 77.
NOTICE
Entering the drop point with the AXIS 20.1, AXIS 30.1 or AXIS 40.1 is merely
informative and does not affect the settings on the fertiliser spreader.
n CAUTION
Danger of injury caused by automatic adjustment of
the drop point!
On the AXIS 50.1 W the alarm move to drop point intervenes.
After actuating the Start/Stop button, the drop point is automati-
cally approached using the electrical setting cylinder to the pre-set
value. This can cause injuries and material damage.
Before actuating the Start/Stop button, ensure that no one
is in the danger area of the machine.
NOTICE
Emergency actuation on the AXIS 50.1 must not stop the adjustment of the
drop point. Otherwise the setting unit for the drop point can suffer damage.