CHAPTER 3
14 RCM - Sprayer and AIM Command FLEX™ II Calibration and Operation Manual
3. Select the NCV Spacing field and enter the distance between nozzle bodies in the units displayed. A nozzle
body spacing value must be entered to continue with the calibration.
4. Select the NCV Tip Size field and select the orifice size of the tips currently installed on the nozzle bodies.
NCV is the tip connected to the AIM Command FLEX™ II NCV.
NOTE: If no tips are installed, or the installed tip size is not available in the drop down menu, select NA as the
Tip Size.
5. Select the Next button to proceed to the NCV Indexing prompt.
AUTOMATIC NCV INDEXING
The automatic NCV indexing process allows the AIM Command FLEX™ II system to automatically configure the
location of each nozzle control valve on the left and right boom circuits and may detect issues with system
connection or NCV setup.
1. The system will begin indexing AIM Command FLEX™ II NCVs from the center of the implement boom and
move out to the end of the left boom. The indexing process automatically repeats for the right boom circuit,
starting from the center and working toward the end of the boom. If an error is detected on either the left or
right boom circuits, the RCM - Sprayer ECU will halt the indexing process and prompt the machine operator to
correct the error before continuing with the calibration wizard. If an error occurs, troubleshoot the issue and
press retry.
2. Select the Next button to continue.
SECTIONS AND FENCE ROW SETUP
Set up the number of sections and fence rows on the application equipment:
1. If available, select the Number of Sections field and enter the number of section on/off valves available for
controlling product application across the boom width.
2. Enable the fence row option if fence row valves are controlled by the system. Select one of the following
options for fence row control from the drop-down menu:
None. No fence rows available or will be controlled by the AIM Command FLEX™ II system.
Fence Valve. Select when the sprayer is equipped to use a ball or solenoid to project spray beyond the working
width of the of the sprayer. This feature is typically used near fence lines, field borders, and boundaries where
the outside spray sections cannot otherwise cover. When Fence Valve is selected, additional parameter options
for adjusting tip size, coverage width, using on-screen activation buttons, and mapping application are
presented.
3. If available and desired, select the Enable On-Screen Fence Row Buttons option to toggle fence row application
directly from the UT screen. If this feature is not activated, fence row sections must be toggled on or off by
another switch or button.
NOTE: Both the desired fence row button/switch and the adjacent section or NCV must be turned on for the
fence row valve to apply product.
This setting is only accessible via the profile calibration wizard.
4. Enable map fence rows as sections to show additional applied area on the coverage map when fence rows are
activated. When this feature is not activated, area covered by fence row sections will not be mapped when
fence rows are toggled on.
NOTE: This setting is only accessible via the profile calibration wizard.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raven Command FLEX II and is the answer not in the manual?

Raven Command FLEX II Specifications

General IconGeneral
BrandRaven
ModelCommand FLEX II
CategoryPaint Sprayer
LanguageEnglish

Related product manuals