System Calibration: Initial Start Up and Calibration Wizard 15
SYSTEM CALIBRATION
5. Enter the additional width covered when only one of the fence row sections is activated, and the spray boom is
at the target height.
NOTE: This measurement assumes that both left and right fence row coverage patterns are equal. This
setting is only accessible via the profile calibration wizard.
6. Set the tip size used for the fence row nozzles.
NOTE: Both left and right fence row tip sizes must be the same.
7. Select the Next button to continue to the Switch Mapping page.
SWITCH SETUP
1. If available, use the drop-down fields for each configured section to assign the switch number for each section.
2. Optionally, if left and right fence rows will be controlled via input switches, select the available switch number
used to control the fence rows.
NOTE: Each section must be assigned to a switch before the Next button will be displayed.
SECTION SETUP
1. If available, enter the width of each section configured for product control.
2. Select the Next button to continue to the Section Offsets page.
SECTION OFFSETS
1. Enable the Rear Implement option if the boom is mounted over or behind the rear axle of the machine or the
pivot point of the pull-type sprayer. If the boom is mounted at the front of the sprayer, or in front of the rear
axle, leave the Rear Implement option unchecked.
2. Measure the distance from the sprayer pivot point to the boom. For example, the center of the sprayer axle or
the rear axle on a self-propelled sprayer to the boom. Enter the measurement in the “B” field in inches
[centimeters].
NOTE: The value entered for the “B” distance must be measured parallel with the direction of vehicle travel.
3. Enable the Left of Center option if the boom is offset to the left of the centerline of the sprayer. If the boom is
centered on the sprayer or is offset to the right, leave the Left of Center option unchecked.
4. If different sections have different fore/aft offsets for the same product, enable the Individual Sections Fore/Aft
Offsets to allow the offsets to be configured for independent sections.
5. Measure the distance from the center of the boom to the centerline of the sprayer. Enter the measurement in
the “A” field in inches [centimeters].
NOTE: The value entered for the “A” distance must be measured perpendicular to the direction of vehicle
travel.
6. When configuring the system for a pull-type sprayer, measure the distance from the pivot point to the
implement hitch. Enter the measurement in the “C” field in inches [centimeters].
NOTE: The value entered for the “C” distance must be measured parallel with the direction of vehicle travel.
7. Press Next to continue with the system calibration.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raven Command FLEX II and is the answer not in the manual?

Raven Command FLEX II Specifications

General IconGeneral
BrandRaven
ModelCommand FLEX II
CategoryPaint Sprayer
LanguageEnglish

Related product manuals