4. Select the NCV Information button on the System Settings page. The following items and menu options will be
available:
SELECT SECTION
Entered the desired section number to inspect or scroll through the sections with the arrow buttons.
SELECT NCV
Enter the desired NCV number to inspect or scroll through NCVs with the arrow buttons.
SECTION STATUS
Reflects the current operating status of the NCVs in the selected section.
Green - All NCVs in the section are operating normally.
Yellow - One or more of the NCVs in the section have an error and may require inspection.
Red - One or more of the NCVs in the section are offline and may require inspection.
SELECT NCV
Enter the desired NCV number to inspect or scroll through the NCVs with the arrow buttons.
NCV STATUS
Reflects the current operating status of the selected NCV.
Green - NCV is operating normally.
Yellow - NCV has an error and may require inspection.
Red - NCV is offline and may require inspection. May also indicate that the system is set to the NCV
Bypass control mode.
NCV ERRORS
NOTE: Not available in the Bypass NCV control mode.
Displays any active NCV errors detected on the system.
NCV HEAT MAP
NOTE: Not available in the Bypass NCV control mode.
Shows an error status chart of the individual NCVs. Review the NCV Status section on page 36 for details about the
NCV status displayed on the heat map.
SECTION HEAT MAP
Shows an error status chart of the sections. Review the Section Status section on page 36 for details about the
section status displayed on the heat map.
NCV SETTINGS
Override NCV Off. Enable for the selected NCV to turn off flow from the NCV. The NCV will still show coverage to
prevent future application in that area. Actual applications rates and volumes are accounted for to ensure
correct rates on active NCVs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raven Command FLEX II and is the answer not in the manual?

Raven Command FLEX II Specifications

General IconGeneral
BrandRaven
ModelCommand FLEX II
CategoryPaint Sprayer
LanguageEnglish

Related product manuals