CHAPTER 8
76 RCM - Sprayer and AIM Command FLEX™ II Calibration and Operation Manual
523234
.13
Pump pressure sensor not
calibrated
• Select correct pump pressure sensor
calibration value.
• Check the pump pressure transducer
connection and cabling for damage. If
necessary, repair or replace cable or replace
pressure transducer.
.16
Pump/boom pressure
differential
• Check strainers between pump and boom
pressure sensor for blockage. Clean if
necessary.
• Check for electric or manual valves between
pump and boom pressure sensors opening
properly.
• Check if pump transducer is functioning
correctly in pressure sensor readings.
• Check if boom transducer is functioning
correctly in pressure sensor readings.
• Check the pressure transducer connections
and cabling for damage. If necessary, replace
the cable or replace pressure sensor.
.4
Pump pressure sensor not
detected
• Check the pump pressure transducer
connection and cabling for damage. If
necessary, replace the cable or replace
pressure sensor.
524082 .31 UT display is offline
• Cycle system power.
• Check cabling and power, ground, and CAN
connections to UT. Repair or replace if
necessary.
Code ID Description Recommended Actions