CHAPTER 8
76 RCM - Sprayer and AIM Command FLEX™ II Calibration and Operation Manual
523234
.13
Pump pressure sensor not
calibrated
Select correct pump pressure sensor
calibration value.
Check the pump pressure transducer
connection and cabling for damage. If
necessary, repair or replace cable or replace
pressure transducer.
.16
Pump/boom pressure
differential
Check strainers between pump and boom
pressure sensor for blockage. Clean if
necessary.
Check for electric or manual valves between
pump and boom pressure sensors opening
properly.
Check if pump transducer is functioning
correctly in pressure sensor readings.
Check if boom transducer is functioning
correctly in pressure sensor readings.
Check the pressure transducer connections
and cabling for damage. If necessary, replace
the cable or replace pressure sensor.
.4
Pump pressure sensor not
detected
Check the pump pressure transducer
connection and cabling for damage. If
necessary, replace the cable or replace
pressure sensor.
524082 .31 UT display is offline
Cycle system power.
Check cabling and power, ground, and CAN
connections to UT. Repair or replace if
necessary.
Code ID Description Recommended Actions