EasyManua.ls Logo

Raven ISO Product Controller II - Page 53

Raven ISO Product Controller II
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
P/N 016-0171-584-H 43
OPERATION
± BUMP
While applying in the automatic control mode, the operator
may elect to display the ± rate or pressure bump softkey in
the softkeys area. Select these softkeys to manually increase
or decrease the target rate or pressure settings by the ±
value set on the presets settings prompt.
Refer to the System Settings Tab - Presets section on page 31
for additional assistance with the rate and pressure ± values
and using the rate or pressure gauges on the home screen to toggle between the rate and pressure ± softkeys.
PRESET
While applying in the automatic control mode, the operator may select
to display the rate or pressure preset softkey in the softkeys area. Select
these softkey to manually toggle between two preset rates or pressures
set using the presets settings prompt.
Refer to the System Settings Tab - Presets section on page 31 for additional assistance with the rate and pressure
preset values and using the rate or pressure gauges on the home screen to toggle between the rate and preset
softkeys.
MAIN PUMP MANUAL CONTROL
In the manual control mode, the rate ± bump and preset softkeys are
replaced with manual pump ± buttons. Select these softkey to manually
increase or decrease the main product pump or injection pump output
during a field application. The Main Product Pump Manual Control
softkeys are replaced by the Injection Pump Manual Control Softkeys
when the injection pump product is selected.
The system will continue to monitor and display the actual application
rate on the home screen.
MANUAL NOZZLE CONTROL BUTTONS
In manual control mode, the pressure ± bump and preset softkeys are replaced with
manual nozzle ± softkeys. Select these softkeys to manually increase or decrease the
nozzle control valve duty cycle during a field application.
The Hawkeye
®
system will continue to monitor and display the actual system pressure on
the home screen.
TOOLS MENU
Select the Tools Menu softkey to access the calibration prompts. See Chapter 4, Hawkeye® Nozzle
Control and Sidekick Pro ICD Setup, for additional assistance with system calibration, features, and
settings.
Rate Pressure
Injection
Pump
Control
Increase
Decrease
Injection
Nozzle
Increase
Decrease
Tools
Menu

Table of Contents

Related product manuals