HAWKEYE® NOZZLE CONTROL AND SIDEKICK PRO ICD SETUP
•Hawkeye
®
HD section control will handle each nozzle like an individual section. Requires Viper 4 and HD
unlock. AccuBoom will only open/close NCV’s. A Master Switch is required to open/close the section valves.
NOTE: The section control mode can only be changed outside of a job. The system will default to Virtual
section control if HD section control is not unlocked.
TIP SIZE OPTION
Use the tip size drop down field to select the size of orifice on the spray boom. This setting is used to assist with
the application information displayed for the equipment operator during field applications. This setting will affect
the speed range, the rate and pressure gauge displays, and ensure the nozzle control system accurately monitors
the application of product during field operations. Entering a NCV tip size is mandatory but the bypass tip size is
optional depending on the machine nozzle configuration.
Fertilizer applicators that do not have tips should select 28% or 32% as the tip size.
CALIBRATE NCV’S
Select the Calibration NCV’s button to restart the calibration wizard. Refer to Chapter 3, System Calibration, for
additional assistance with completing the initial calibration of the Hawkeye
®
nozzle control system.
Pressing Calibrate NCV’s does not reset the Hawkeye
®
system default settings. Refer to System Information Tab
section on page 38 for assistance with restoring default system settings.
INJECTION WIZARD
Select the Injection Wizard button to re-assign the Sidekick Pro ICD injection products. Refer to Injection Wizard
section on page 18 for additional assistance with completing the setup of the Sidekick Pro ICD direct injection
pumps.
Restarting injection wizard does not reset the Sidekick Pro ICD system default settings. Refer to System
Information Tab section on page 38 for additional information on restoring default system settings.
TOTAL AND SECTION WIDTH DISPLAYS
Total Width. The total width value displays the sum of the currently programmed section widths.
Section Widths. The widths of individual sections configured for the Hawkeye
®
nozzle control system will be
displayed below the total width.
NOTE: Restart the calibration wizard to adjust or modify the section widths or the total width of the
implement.
Switch Mapping. Sections mapped to a compatible switch box for manual section control will display using
different color section width displays. Touch the Help icon on the Equipment Settings prompt to view a switch map
legend.
NOTE: An ISOBUS boom interface/speed sense ECU, Product Controller II ECU, Raven ISOBUS switch box, or
a bridge ECU must be connected with the Hawkeye
®
system. To configure custom switch mapping,
restart the calibration wizard by resetting Defaults, select the proper Machine Make, Select a Custom
Profile, and follow the on screen prompts for assistance with mapping sections to switch box
functions during the calibration wizard.