CHAPTER 8
60 ISO Product Controller II and Hawkeye Operation Manual
FIGURE 3. Flow Meter Extension Cable Pin Diagram (Con-X-All)
TABLE 6. Flow Meter with Deutsch DT Connector
TABLE 7. Flow Meter with Deutsch DTM Connector
TEST THE FLOW METER CABLE
To test the flow meter cable:
1. Open the UT Menu and select the Hawkeye
®
Menu button.
2. From the home screen, select the Tools Menu softkey along the right side of the display.
3. Select the System Settings tab along the top of the display and select the Product Control Settings button.
4. Enter a value of one for the Meter Cal value.
5. Select the Home softkey along the right side of the display and then select the Tally Registers softkey.
6. Monitor the Total Volume value while testing the cable.
7. Toggle at least one section switch and the master switch to the on position.
Pin Function
A+ VDC
B0 VDC
C Signal Out
Pin Function
1Signal
2Ground
35 VDC
Keyway
5 VDC
5 VDC
2 o’clock
Ground
10
o’clock
Power
6 o’clock
Signal
Hawkeye Menu
Tools Menu
System
Settings
Home Tally
Registers
Product
Control
Settings
UT Menu