2
Manual No. 016-0171-391 5
Introduction
Integrated Motor Control Node
Sidekick Pro features an integrated motor control node mounted directly on the pump housing for simplified
installation and enhanced performance. The control node features status LEDs which provide status and CAN
communication information which the operator may be able to use during calibration or system
troubleshooting.
Integrated Calibration Switch
The integrated motor control node also features a sealed calibration switch. The sealed calibration switch
allows the operator to begin the pump calibration process by passing a metallic object, such as a screwdriver,
across the switch sensor on the Sidekick Pro injection pump. This feature allows the operator to run multiple
calibration tests quickly and easily and ensure the system is ready for operation.
Note: Calibration may also be initiated from the control console in the vehicle cab. See the Calibrate the
Injection Pump section on page 32 for a detailed calibration procedure.
The calibration status LED light will flash when the calibration sensor registers a metallic object by the switch.
Pass the metal object past the sensor twice to initiate a pump calibration.
FIGURE 2. Motor Control Node Calibration Sensor
Calibration
Sensor Location
Calibration
Status LED