Setting Application
Mode and Injection
Diagnostics
Review the specific section for the control console for details on locating and using the injection diagnostics
screens with the injection pump.
Viper Pro
Note: Raven Sidekick Pro injection pumps (P/N 063-0173-081 or 063-0173-103) are equipped with
diagnostic and flow monitoring features for CANbus control consoles. To access complete
diagnostic capabilities for the Sidekick Pro injection system, the Viper Pro must have software
version 3.3.0.0 or newer. Software updates for the control console may be downloaded from the
Raven Applied Technology Division web site:
http://www.ravenprecision.com/Support/Software/index2.jsp
Application Mode Setup
1. Touch within the product control area at the bottom of the main screen.
2. Select the product node corresponding to the injected product and touch within data box 1.
3. Touch the Next button to display the following screen.
4. The Vacuum/Bin Alarm is enabled by default when a motor control node is detected on the CANbus.
Deselect this option to disable the audible alarm for injected products.
5. When enabled, the Agitator option will send power to an agitator motor via the CAN motor control cable.
See Figure 11 on page 21.