5
Manual No. 016-0171-391 41
Setting Application Mode and Injection Diagnostics
Injection Diagnostics Display
1. Press the DATA MENU key until the Run Time Diagnostics screen is displayed.
Press - PSI. These values are the pressure observed during the pressure stroke of the left and right pump
heads.
Vacuum - PSI. These values are the pressure observed during the vacuum stroke of the left and right pump
heads.
FER. The FER (flow to encoder ratio) value is a tool used in conjunction with the FER Error Cal to identify the
relative efficiency of the pump. This area displays a value between 0 and 100.
Note: This number is an indicator of pump health and cannot be used to meter flow from the pump.
Motor RPM. The current RPM of the injection pump motor is displayed in this area.
Temperature. The temperature of the motor control node is displayed in this area. This value, in conjunction
with the motor RPM, may be useful to help determine how hard the pump is being driven.
Voltage. The high current voltage detected by the CAN motor control node is displayed in this area.
% PWM. The percent PWM value may be used to determine how hard the pump is being driven. A value of
100 indicates the pump is being driven at the maximum.
Hours. This value represents the number of hours which the injection node has been engaged for operation.
PROD NODE 2-INJECTION
RUN TIME INFO
PUMP-PRESS 12.0
FER 99.5
MOTOR RPM 107
TEMP 99.3
VOLTAGE 14.2
% PWM 87.5
HOURS 23.6
FLOW ERROR CODE #
KEY 1 - START CAL
KEY 2 - START PRIMING