36
Steer Pulse Time
The Steer Pulse Time screen allows you to set the time that it takes to
deactivate the controller when the pressure switch or flow switch is
activated. This feature filters out any small spikes in pressure that can
occur when the SmarTrax controller is engaged. This setting displays in
milliseconds (ms) and represents the amount of time that the controller
must read a high-pressure spike before disengaging the system. If the
system disengages while traveling through the field, increase the delay
setting to filter out small spikes in the hydraulic system.
Setting the Steer Pulse Time
Press the Left or Right arrow to set the Steer Pulse Time to the desired
value.
Note:
The factory stop switch delay setting is 150ms.
An adjustment may also need to be made on the pressure
switch.