Mechanical
Problems
Mechanical problems with the vehicle can cause the SmarTrax controller to
not work properly. Before you start troubleshooting the system, trace all
hoses and wires to make sure that they are connected to the proper ports
and connectors. You can avoid many potential problems by making sure
that all wires and hoses are properly connected.
The following table lists some common mechanical problems and the
corrective action needed to fix the problem.
SPS Backwards The SPS has been calibrated
backwards.
Recalibrate the SPS
by resetting the left
center and right
positions.
Gain Diff High The calibration of the left
hydraulics was inconsistent
with the right hydraulics.
Perform another
hydraulic calibration.
Valid Pts Low The calibration did not find
valid data.
Perform another
hydraulic calibration.
Error Message Problem Solution
Note: Make any adjustments to the hydraulic components
in small increments so that you can identify problems and
solutions correctly. Perform only one change at a time to
better troubleshoot the issue.
Mechanical Problem Solution
SmarTrax will not
power up.
1. Turn the key to the On position.
2. Check the fuses.
3. Check the battery connections.
4. Test for +12VDC using a voltmeter.
5. Replace the controller.
SmarTrax arrow keys
do not function.
1. Unplug the power cable from the back of the
controller and then reattach it and power up.
2. Replace the controller.
SPS or Yaw count does
not change.
1. Inspect the SPS cable and controller cable for
proper pinning and connection.
2. Inspect and replace the SPS, if necessary.
3. Replace the controller.
Cannot enter or change
the initial settings on
the controller.
1. Turn off the power to the controller and then turn
it back on.
2. Verify that the Lockout Setting is Off.
3. Replace the controller.