Configurations
16
102-127108955 V1.1 71/ 102
→ When locked The parameter defines how the door is to react in the operat-
ing mode
‘Locked’
.
→ Disabled X The door closes with motor drive and programmed closing
speed.
→ Active In the locked operating mode, the door can be opened manu-
ally. The closure is then carried by spring tension (night
watchman).
→ When Automatic The parameter defines how the door is to react in the operat-
ing mode
‘Automatic’
.
→ Disabled X The door closes with motor drive and programmed closing
speed.
→ Active In the automatic operating mode, the door can be opened ma-
nually. The closure is then carried out by spring tension.
→ Collision Activated: If the door leaf stands still for more than 1 s during
closure, motor-driven re-opening follows. Effective only when
motorised opening is allowed, e.g.
Manual/Active sensors
.
→ Disabled X The door stops when hitting an obstacle during closing.
→ Active If the door leaf stands still for more than 1 s during closure,
motor-driven re-opening follows.
▪ Effective only when motorised opening is allowed,
e.g.
Manual/Active sensors
.
→ Assisted closure This parameter determines the behaviour of the drive when
closing in ‘Manual mode’ shortly before complete closure.
▪ Support for wind load, over- and under pressure,
electric door openers and heavily dimensioned door
seals.
→ Disabled X The door closes with motor drive and programmed closing
speed.
→ Constant Constant: unchanging power-assisted closing force for the final
10°.
→ Increasing Increasing, power-assisted closing force, if the closure is inhib-
ited within the last 10 °.
→ Door stop Rapidly-increasing, power-assisted closing force for the last 2°.
→ Slow, increasing Slow closing with increasing, power-assisted closing force, if
the closure is inhibited within the last 10°.
→ Slow, Door stop Slow closing with rapidly-increasing, power-assisted closing
force for the last 2°.