Universal Arm as Push Application
For installing Universal arm as Push application, what is critical is that the bottom of the header be mounted in line with
the bottom of the top jamb door stop. This is to ensure that the arm has enough clearance when swinging through the
upper jambs.
Repeat Steps in Pull application:
STEP 1 - Mark closed position
IN PUSH APPLICATION,
BOTTOM OF HEADER MUST
BE FLUSH WITH DOOR STOP
(ENSURE ARM CLEARS FROM
FRAME DURING SWING)
Close the door fully. Mark the spot where the arm touch the closed door.
In this closed position, mark the spot where roller would touch door (directly below where the arm meets the door).
STEP 2 - Mark open position
Open the door to full open and set switch to Hold Open.
Fit the Universal arm to the drive shaft (Spindle) at the full open position, but do not tighten the M6 x 20mm Socket
Cap Screw all the way This is to allow the arm some freedom/flexibility.
Mark the spot where the roller would touch the door (directly below where the arm meets the door).
This is the open position.
STEP 3 - Fitting Pull Track
For a push (with door opening 90 degrees), these two marks will be around 10-12 inches apart.
Remove two ends caps and fit the extended pull track to cover the 1st and 2nd mark.
Fix to the door, using the #14-10x1” Phillips/Square Pan Self-Tapping Screws provided in the screw pack (or the
fastener of your choice). You may center the roller track in the door for visual aesthetics if the door width allows, but
ensure the track covers the open and close marks for correct operation.
Re-attach the two end caps to hide the screws.
STEP 4 - Attaching Universal Arm
Attach the roller shaft to the arm as shown, making sure the set screw is tightened into the groove on the roller shaft.
This will ensure that the arm and shaft do not dislocate during operation.
Tighten the M6 x 20mm socket cap screw for the male and female splines to grip correctly.
Turn switch to Automatic or ON, to test and adjust if necessary.
Note that for door openings larger than 90 degrees, the universal arm MUST be used as Pull application.
Make sure Pull Track is installed level with the header. This is to ensure the roller stays inside the
track during opening and closing, prolonging the life of the roller.
3.0 ARM INSTALLATION