R8C/20 Group, R8C/21 Group 14. Timers
Rev.2.00 Aug 27, 2008 Page 172 of 458
REJ09B0250-0200
Figure 14.34 Registers TRDSTR and TRDMR in Input Capture Function
Timer RD Start Register
(1)
Symbol Address After Reset
TRDSTR
0137h 11111100b
Bit Symbol Bit Name Function RW
NOTE:
1.
b3 b2
CSEL1
b1 b0
Set to 1 in the input capture function
TRD1 count operation select bit Set to 1 in the input capture function
Set the TRDSTR register using the MOV instruction (do not use the bit handling instruction). Refer to
14.3.12.1
TRDSTR Re gis te r
of
Notes on Timer RD.
RW
RW
Nothing is assigned. If necessary, set to 0.
When read, the content is 1.
TRD0 count operation select bit
b7 b6 b5 b4
(b7 - b4)
CSEL0
11
TSTART0 RW
TSTART1 RW
TRD1 count start flag 0 : Count stops
1 : Count starts
TRD0 count start flag 0 : Count stops
1 : Count starts
Timer RD Mode Register
Symbol Address After Reset
TRDMR
0138h 00001110b
Bit Symbol Bit Name Function RW
b3 b2
BFD0
b1 b0
SYNC
b7 b6 b5 b4
RW
(b3 - b1)
Timer RD synchronous bit 0 : TRD0 and TRD1 registers
operate independently
1 : TRD0 and TRD1 registers
operate synchronously
Nothing is assigned. If necessary, set to 0.
When read, the content is 1.
RW
TRDGRD0 register function
selection bit
0 : General register
1 : Buffer register of TRDGRB0 register
TRDGRC1 register function
selection bit
0 : General register
1 : Buffer register of TRDGRA1 register
RW
TRDGRC0 register function
selection bit
0 : General register
1 : Buffer register of TRDGRA0 register
BFC0 RW
RW
BFC1
BFD1
TRDGRD1 register function
selection bit
0 : General register
1 : Buffer register of TRDGRB1 register

Table of Contents