Bit Switches - 6
SM 127 D418
Fax Option
Type 9001
D418
IP Fax Switch 03 (SP No. 1-111-004)
No. Function Comments
7 Not used Do not change this setting.
IP Fax Switch 04 (SP No. 1-111-005)
No. Function Comments
0-3 TCF error threshold
Sets the TCF error threshold level. [00 to 0f]
The default is "1111" (0fH).
4-7 Not used Do not change these settings.
IP Fax Switch 05 (SP No. 1-111-006)
No. Function Comments
Modem bit rate setting for transmission
(kbps)
Bit 3 Bit 2 Bit 1 Bit 0 kbps
0 0 0 1 2.4
0 0 1 1 4.8
0 0 1 1 7.2
0 1 0 0 9.6
0 1 0 1 12.0
0 1 1 0 14.4
0 1 1 1 16.8
1 0 0 0 19.2
1 0 0 1 21.6
0-3
1 0 1 0 24.0
Sets the modem bit rate for
transmission. The default is "0110"
(14.4K bps).