Page #1142 background image
Bit Switches - 6
SM 129 D418
Fax Option
Type 9001
D418
IP Fax Switch 06 (SP No. 1-111-007)
No. Function Comments
0 1 0 0 V.27ter, V.29, V.17/V.33
Other settings - Not used
IP Fax Switch 07 (SP No. 1-111-008)
No. Function Comments
0
TSI information
0: Not added, 1: Added
Adds or does not add TSI information to
NSS(S).
1
DCN transmission setting at T1
timeout
0: Not transmitted
1: Transmitted
Transmits or does not transmit DCN at T1
timeout.
2 Not used Do not change this setting.
3
Hang up setting at DIS reception
disabled
0: No hang up
1: Hang up after transmitting DCN
Sets whether the machine disconnects after
DIS reception.
4
Number of times for training
0: 1 time, 1: 2 times
Selects the number of times training is done
at the same bit rate.
5
Space CSI transmission setting at
no CSI registration
0: Not transmitted
1: Transmitted
When "0" is selected, frame data is enabled.
When "1" is selected, the transmitted data is
all spaces.
6-7 Not used Do not change these settings.

Table of Contents

Other manuals for Ricoh Aficio MP 8001 SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh Aficio MP 8001 SP and is the answer not in the manual?

Ricoh Aficio MP 8001 SP Specifications

General IconGeneral
BrandRicoh
ModelAficio MP 8001 SP
CategoryPrinter
LanguageEnglish

Related product manuals