NCU Parameters
SM 137 D418
Fax Option
Type 9001
D418
Address Function Unit Remarks
680537
International dial tone frequency
lower limit (low byte)
disabled.
680538
International dial tone detection
time
680539
International dial tone reset time
(LOW)
68053A
International dial tone reset time
(HIGH)
68053B
International dial tone
continuous tone time
68053C
International dial tone
permissible drop time
If 680538 contains FF, the
machine pauses for the
pause time (68053D /
68053E).
Belgium: See Note 2.
68053D
International dial wait interval
(LOW)
68053E
International dial wait interval
(HIGH)
20 ms
68053F
Country dial tone upper
frequency limit (HIGH)
680540
Country dial tone upper
frequency limit (LOW)
If both addresses contain
FF(H), tone detection is
disabled.
680541
Country dial tone lower
frequency limit (HIGH)
680542
Country dial tone lower
frequency limit (LOW)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
680543 Country dial tone detection time
680544
Country dial tone reset time
(LOW)
20 ms If 680543 contains FF, the
machine pauses for the
pause time (680548 /