Service Call Conditions
SM Appendix 3-29 D062/D063/D065/D066
Appendix:
Service Call
Conditions
than 1 second. The temperature
is read 10 times every second.
(at 0.1 s intervals).
BICU control board defective
Fusing lamp error
555 A
After the start of the warmup
cycle, a fusing lamp was at full
power for 1.8 s but the hot roller
did not turn.
Thermistor bent, out of position
Fusing lamp disconnected
Circuit breaker opened
Zero cross signal error -
557 C
High frequency noise was
detected on the power line.
No action required. The SC code is
logged and the operation of the
machine is not affected.
Fusing jam: 3 counts
559 A
At the fusing exit sensor the
paper was detected late for three
pulse counts (lag error), and
SP1159 was on.
If this SC occurs, the machine
cannot be used until the service
technician cancels the SC code.
This SC occurs only if SP1159 has
been set to "1" (On). (Default: 0
(Off)).
Fusing pressure release motor error
569 D
During copying, the HP sensor
could not detect the actuator,
tried again 3 times and could not
detect.
Motor lock because of too much
load
Motor driver defective
HP sensor defective, disconnected,
connector defective, harness
damaged