Service Call Conditions
SM Appendix 3-55 D062/D063/D065/D066
Appendix:
Service Call
Conditions
0008 Self-diagnostic Error: CPU: System Call Exception GW
0612 Self-diagnostic Error: CPU: ASIC Interrupt Error GW
820 D
System program defective
Controller board defective
Optional board defective
Replace controller firmware
Note: For more details about this SC code error, execute SP5990 to print
an SMC report so you can read the error code. The error code is not
displayed on the operation panel.
For more details about this SC code error, execute SP5990 to print an SMC report
so you can read the error code. The error code is not displayed on the operation
panel.
Self-diagnostic error: ASIC
The Write & Verify check of the ASIC
returned an error.
Note: The main ASIC module on the
controller board controls the bus of
the ROM device.
Replace the controller board
0B00 ASIC register check error
821 D
0x0Bnn ASIC is not detected.
For more details about this SC code error, execute SP5990 to print an SMC report
so you can read the error code. The error code is not displayed on the operation
panel.